VD4 Series 40.5kV Technical Parameter Table |
|||||||||||
| Technical parameters | 40.5 kV series | ||||||||||
| standard | GB/T 1984, IEC 62271-100 | ||||||||||
| Rated voltage (Ur) | 40.5 kV | ||||||||||
| Power frequency withstand voltage (Ud) | 95 kV (1 minute) | ||||||||||
| Lightning impulse withstand voltage (Up) | 185 kV | ||||||||||
| Rated frequency (fr) | 50/60 Hz | ||||||||||
| Rated current (Ir) (at an ambient temperature of 40°C) |
1250 A, 1600 A, 2000 A, 2500 A | ||||||||||
| Rated breaking current (Isc) | 25 kA, 31.5 kA | ||||||||||
| Rated short-time withstand current (Ik) | 25 kA, 31.5 kA (4s) | ||||||||||
| Rated peak withstand current (Ip) | 63 kA, 80 kA | ||||||||||
| Operation sequence | O-0.3s-CO-180s-CO | ||||||||||
| Opening time | 30...45 ms | ||||||||||
| Closing time | 55...67 ms | ||||||||||
| Opening and closing time | ≤ 60 ms | ||||||||||
| Mechanical life | 10,000 times | ||||||||||
| External dimensions (H×W×D) (typical values for handcart type) |
1515 × 1055 × 710 mm | ||||||||||
| Phase spacing | 360 mm | ||||||||||
| Reference weight | 240 - 320 kg | ||||||||||
| Note : The 40.5kV circuit breaker uses a special planar spiral spring operating mechanism instead of the common EL mechanism to meet the requirements of higher voltage levels. | |||||||||||

| Size |





| Standard VD4 40.5kV Complete Model List | |||||||||||
| The 40.5kV VD4 standard series covers the following specifications: | |||||||||||
| 1. 1250A specification (current code 12) | |||||||||||
| Breaking current | Phase spacing | Handcart model | Fixed model | ||||||||
| 25 kA | P280 / P360 | VD4 40.12.25 P280 | VD4 40.12.25 P360 | ||||||||
| 31.5 kA | P280 / P360 | VD4 40.12.31 P280 | VD4 40.12.31 P360 | ||||||||
| 2. 1600A specification (current code 16) | |||||||||||
| Breaking current | Phase spacing | Handcart model | Fixed model | ||||||||
| 25 kA | P280 / P360 | VD4 40.16.25 P280 | VD4 40.16.25 P360 | ||||||||
| 31.5 kA | P280 / P360 | VD4 40.16.31 P280 | VD4 40.16.31 P360 | ||||||||
| Example of specific models: | |||||||||||
| VD4 40.16.25 P6 110NST (Fixed type, order number: 51000645) | |||||||||||
| VD4 40.16.25 P280 (handcart type) | |||||||||||
| 3. 2000A specification (current code 20) | |||||||||||
| Breaking current | Phase spacing | Handcart model | Fixed model | ||||||||
| 25 kA | P280 / P360 | VD4 40.20.25 P280 | VD4 40.20.25 P360 | ||||||||
| 31.5 kA | P280 / P360 | VD4 40.20.31 P280 | VD4 40.20.31 P360 | ||||||||
| 4. 2500A specification (current code 25) | |||||||||||
| Breaking current | Phase spacing | Handcart model | Fixed model | ||||||||
| 25 kA | P280 / P360 | VD4 40.25.25 P280 | VD4 40.25.25 P360 | ||||||||
| 31.5 kA | P280 / P360 | VD4 40.25.31 P280 | VD4 40.25.31 P360 | ||||||||
| 5. 3150A specification (current code 31) | |||||||||||
| Breaking current | Phase spacing | Handcart model | Fixed model | ||||||||
| 25 kA | P280 / P360 | VD4 40.31.25 P280 | VD4 40.31.25 P360 | ||||||||
| 31.5 kA | P280 / P360 | VD4 40.31.31 P280 | VD4 40.31.31 P360 | ||||||||