HomeProductsABBABB MCCB SeriesABB Tmax T-Series molded case circuit breakers are versatile low-voltage power distribution devices, providing protection for all scenarios from 1000V DC to 1150V AC.

ABB Tmax T-Series molded case circuit breakers are versatile low-voltage power distribution devices, providing protection for all scenarios from 1000V DC to 1150V AC.

ABB Tmax T-Series molded case circuit breakers are all-around low-voltage protection platforms integrating high voltage compatibility (up to 1150V AC/1000V DC), wide current coverage (160A-3200A), compact modular design (T4/T5/T6 with a uniform depth of 103.5mm), and intelligent electronic tripping technology. They can not only cope with harsh industrial environments such as underground mining, marine and electrified transportation, but also provide highly reliable power distribution and energy management capabilities in photovoltaic energy storage, data centers, and critical infrastructure through innovative technologies such as EFDP fault prediction and wideband protection (VF series). They are a time-tested choice for molded case circuit breakers for users worldwide.

Product Details

Tmax T-series model overview and technical specifications:

T5, T6, and T7 are three main models in ABB's Tmax T series, covering medium to high current applications from 400A to 1600A. They share a modular design philosophy and a unified accessory system, and are widely used in industrial power distribution, motor protection, new energy, and special high-voltage applications.

T5 Series: The King of High-Performance Size Ratio
The T5 is the most well-rounded model in the Tmax series, achieving extremely high breaking capacity within a compact size, with rated currents covering both 400A and 630A levels.
Parameters T5 400 T5 630
Frame current (Iu) 400 A 630 A
Extreme number 3P / 4P 3P / 4P
Rated insulation voltage (Ui) 1150 V AC 1150 V AC
Rated impulse withstand voltage (Uimp) 8 kV 8 kV
Rated operating voltage (Ue) Maximum 1150 V AC / 1000 V DC Maximum 1150 V AC / 1000 V DC
Division ability (ICU) 415V AC: up to 200 kA 415V AC: up to 200 kA
690V AC: 80 kA 690V AC: 50 kA
1000V AC: 20 kA 1000V AC: 20 kA
1150V AC: 12 kA 1150V AC: 12 kA
Use category Class B (400A) / Class A (630A) Category A
Mechanical life 20,000 times 20,000 times
Number of operations per hour 120 times 120 times
External dimensions (W×D×H) 140 × 103.5 × 205 mm (3P) 140 × 103.5 × 205 mm (3P)
Weight (fixed) 3.25 kg (3P) / 4.15 kg (4P) 3.25 kg (3P) / 4.15 kg (4P)

 

Trip unit options
The T5 supports multiple types of trip units, allowing for flexible selection based on protection requirements:
Trip unit type Model
Thermomagnetic TMD / TMA
Electronic PR221DS
Electronic PR222DS/P
Motor protection PR222MP

 

Installation method
Fixed (F) : Standard configuration
Insert-type (P) : T5 400 optional
Extractable (W) : T5 400 optional

 

Terminal block options
Front terminal block (F)
Copper cable front terminal (FC Cu)
Copper/aluminum cable front-end terminal block (FC CuAl)
Extended front terminal block (EF)
Extended front terminal block (ES)
Rear horizontal terminal block (HR)

 

 

Dimensions (mm)
TmaxT5 - Fixed
 
TmaxT5 - Fixed

 

Dimensions (mm)
Tmax T5 - Insertion-Type
 
Tmax T5 - Insertion-Type

 

Dimensions (mm)
TmaxT5 - Pull-out
 
TmaxT5 - Pull-out

 

T6 Series: High Current Compact Circuit Breaker
The T6 increases the rated current of the Tmax series to the 800A-1000A level, while maintaining the same 103.5mm depth as the T4/T5, achieving a high degree of uniformity.
Parameters T6 630 T6 800
Frame current (Iu) 630 A 800 A / 1000 A
Extreme number 3P / 4P 3P / 4P
Rated insulation voltage (Ui) 1000 V AC 1000 V AC
Rated impulse withstand voltage (Uimp) 8 kV 8 kV
Rated operating voltage (Ue) Maximum 1000 V AC / 750 V DC Maximum 1000 V AC / 750 V DC
Division ability (ICU) 415V AC: Maximum 120 kA;
690V AC: 50 kA;
1000V AC: 12 kA
415V AC: Maximum 100 kA;
690V AC: 40 kA;
1000V AC: 12 kA
Use category Category B Category B
Mechanical life 20,000 times 20,000 times
Number of operations per hour 120 times 120 times
External dimensions (W×D×H) 210 × 103.5 × 268 mm (3P) 210 × 103.5 × 268 mm (3P)
Weight (fixed) 9.5 kg (3P) / 12 kg (4P) 9.5 kg (3P) / 12 kg (4P)

 

Trip unit options
The T6's trip unit system is highly consistent with that of the T4/T5, and also supports configurations with higher current ratings.
Trip unit type CModel Applicable current Features
Thermomagnetic TMA 630A / 800A Adjustable thermal-magnetic protection, suitable for AC/DC.
Electronic PR221DS 630A / 800A LSI Electronic Protection
Electronic PR222DS/P 630A / 800A LSI or LSIG power distribution protection
Motor protection PR222MP 630A Dedicated motor protection with thermistor input

 

Installation method
Fixed (F) : Standard configuration
Extractable (W): 630A and 800A optional

 

Terminal block options
Front terminal block (F)
Copper cable front terminal (FC Cu)
Copper/aluminum cable front-end terminal block (FC CuAl)
Rear terminal block (R)
Rear horizontal terminal block (HR)

 

Dimensions (mm)
TmaxT6 - Fixed
TmaxT6 - Fixed

 

Dimensions (mm)
TmaxT6 (630A-800A) - Pull-out
TmaxT6 (630A-800A) - Pull-out

 

T7 Series: Flagship Molded Case Circuit Breaker
The T7 is the flagship model in the Tmax series, with rated currents ranging from 800A to 1600A, filling the gap between molded case circuit breakers and air circuit breakers. The T7 boasts more powerful functions and more flexible installation options.
Parameters T7 (800-1600A)
Frame current (Iu) 800 / 1000 / 1250 / 1600 A
Extreme number 3P / 4P
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 8 kV
Rated operating voltage (Ue) Up to 690 V AC
Division ability (ICU) 415V AC: Maximum 150 kA
690V AC: 60 kA
Use category Category B
Mechanical life 20,000 times
Number of operations per hour 60 times

 

Trip Unit Options – Intelligent Electronic Trip Unit
One of the highlights of the T7 is its advanced electronic trip unit, available in two models: basic and advanced.
Trip unit model Type Core Functions
PR231/P Basic type DIP switches set protection thresholds, and LEDs indicate the fault type.
PR232/P Basic type DIP switch settings support more protection functions
PR331/P Advanced Equipped with a rated current connector, the rated current can be changed by replacing the connector, and an LCD display screen.
PR332/P Advanced Wide-range LCD display with data logger function, capable of recording all events and electrical values ​​for easy fault analysis.

 

Advanced features
Rating Module : PR331/PR332 supports changing the rated current In of the circuit breaker by replacing the module, without replacing the entire circuit breaker.
Data logger : The PR332 can record historical events and electrical parameters, facilitating later maintenance and analysis.

 

Installation method
Fixed (F) : Standard configuration, supports vertical/horizontal installation.
Pull-out type (W): Optional, equipped with a new shake-out system for quick and safe operation.

 

Mechanical properties
Manual operation : Standard toggle handle
Electric operation : Electric operating mechanism is optional.
Mechanical interlocking : Supports mechanical interlocking between two T7 circuit breakers or between a T7 circuit breaker and an air circuit breaker via flexible cables.

 

Terminal block options
Front terminal block
Rear horizontal terminal block (HR)
Rear Vertical Terminal Block (VR)
Extended front terminal block (EF/ES)

 

 

Dimensions (mm)
TmaxT7 - Fixed
TmaxT7 - Fixed
Dimensions (mm)
TmaxT7 - Fixed
TmaxT7 - Fixed
Dimensions (mm)
Tmax T7 - Pull-out
Tmax T7 - Pull-out
Dimensions (mm)
Tmax T7M - Pull-out
Tmax T7M - Pull-out

 

Comparison Summary of Three Models
Comparison Dimensions T5 T6 T7
Current range 400A, 630A 630A, 800A, 1000A 800A, 1000A, 1250A, 1600A
Maximum splitting capacity (415V) 200 kA 120 kA 150 kA
Special voltage capability 1150V AC / 1000V DC 1000V AC / 750V DC 690V AC standard
Unified Depth 103.5 mm 103.5 mm Larger (not uniform)
Trip unit type Thermal/Magnetic/Electronic/Motor Protection Thermal/Magnetic/Electronic/Motor Protection Electronic (PR23x/PR33x)
Pull-out optional T5 400 optional Optional Optional
Applicable Scenarios Industrial power distribution, high voltage special applications High-current power distribution and motor control center Main incoming switch, critical power supply, and electric operation scenarios

 

Application scenario suggestions
Model Recommended application scenarios
T5 Main switches for industrial power distribution cabinets, high-voltage special applications (such as 1150V AC/1000V DC mining and tunnel lighting), and input/output protection for frequency converters.
T6 High-capacity distribution cabinets, motor control center (MCC), generator protection, 690V industrial systems
T7 Low-voltage incoming main switch, upstream and downstream protection systems in conjunction with air circuit breakers, applications requiring electrically operated operation, and critical power supply systems requiring data recording and analysis.

Online Inquiry

Related Products

ABB Tmax XT series molded case circuit breakers: built to withstand harsh environments and safeguard marine and new energy applications.

ABB Tmax XT series molded case circuit breakers: built to withstand harsh environments and safeguard marine and new energy applications.

The ABB Tmax XT series represents a new generation of molded case circuit breakers (MCCBs) designed for modern power distribution and motor protection. Covering rated currents from 160A to 1600A, the series combines three core advantages: compact size, high breaking capacity, and intelligent capabilities. Built on a platform engineered for high performance, the entire series features integrated Ekip electronic trip units that support precise energy metering, thermal memory, and Bluetooth/NFC communication, enabling seamless integration with the ABB Ability™ cloud platform. Whether applied in low-voltage distribution, wind and solar power, marine and port operations, or industrial drive systems, the Tmax XT series delivers comprehensive protection solutions—ranging from cost-effective to high-performance options—thanks to its superior breaking capacity, flexible accessory system, and robust environmental adaptability, ensuring safe, continuous, and efficient system operation even under demanding conditions.

ABB SACE Isomax S series molded case circuit breakers, covering the full current range from 125A to 3200A

ABB SACE Isomax S series molded case circuit breakers, covering the full current range from 125A to 3200A

The ABB SACE Isomax S series comprises eight frame sizes (S1 through S8) with current ratings ranging from 125A to 3200A and ultimate breaking capacities up to 200kA. It supports fixed, plug-in, and withdrawable versions, as well as 1000V AC/DC applications, and offers an optional PR212/P electronic trip unit for overload, short-circuit, and earth-fault protection.

ABB Tmax T-Series molded case circuit breakers are versatile low-voltage power distribution devices, providing protection for all scenarios from 1000V DC to 1150V AC.

ABB Tmax T-Series molded case circuit breakers are versatile low-voltage power distribution devices, providing protection for all scenarios from 1000V DC to 1150V AC.

ABB Tmax T-Series molded case circuit breakers are all-around low-voltage protection platforms integrating high voltage compatibility (up to 1150V AC/1000V DC), wide current coverage (160A-3200A), compact modular design (T4/T5/T6 with a uniform depth of 103.5mm), and intelligent electronic tripping technology. They can not only cope with harsh industrial environments such as underground mining, marine and electrified transportation, but also provide highly reliable power distribution and energy management capabilities in photovoltaic energy storage, data centers, and critical infrastructure through innovative technologies such as EFDP fault prediction and wideband protection (VF series). They are a time-tested choice for molded case circuit breakers for users worldwide.

WhatsApp: +852-90635157
WeChat

+852-90635157

song@zhongkong-electric.com